I've lived off grid for 22 years, in a treehouse in a remote part of Hawaii Island. If you're planning power for a small cabin, the first question is usually how big a system it needs. My honest answer is that it depends on what you run and where the cabin is, and that the arithmetic is simple enough to do yourself. This page walks through it the way I'd do it, with the sources, for a weekend cabin and a full-time cabin. If you see a mistake, I'd like to hear about it.
The five steps, in order
My system is 1,780 W of panels, a 60 A charge controller at 12 V, a 4.02 kWh LiFePO4 bank (four 314 Ah cells in series, 12.8 V), a 3,000 W pure sine inverter and a Honda EU2200i backup generator. It runs two laptops, a monitor, Starlink and networking. Planning on 80% of the bank leaves about 3,215 Wh usable.
It isn't a template. It's one working system, and it's useful as a yardstick for the numbers below. Two honest notes about it. First, PowMr's manual lists the controller's maximum panel input at 12 V as 720 W, well under my 1,780 W array.[5] How much of the array reaches the battery on a bright day depends on wiring I haven't documented here, so I won't put a number on it. If you're buying for a new cabin, match the controller's listed input to the array on paper first. Second, the generator is a requirement for me, not an extra. You'll see why in the worked examples.
Energy per day is watts times hours. Virginia Cooperative Extension gives it as wattage x hours used per day / 1,000 = daily kWh.[2] I keep it in Wh, because small cabin loads are small numbers.
Here are the two examples. The quantities and hours are my assumptions for an ordinary small cabin. Swap in your own.
| Load | Watts | Qty | Hours/day | Wh/day | Where the watts come from |
|---|---|---|---|---|---|
| LED lights | 9 | 4 | 4 | 144 | assumed 9 W bulbs; check yours |
| Phone charging | 10 | 2 | 2 | 40 | assumed |
| Laptop | 50 | 1 | 3 | 150 | VT Extension list[2] |
| Starlink Mini (high end of average) | 40 | 1 | 6 | 240 | Starlink spec 25–40 W[3] |
| Ceiling fan | 65 | 1 | 4 | 260 | low end of VT range 65–175 W[2] |
| AC loads | 834 | ||||
| From the battery at 90% inverter efficiency | 927 | 834 / 0.90 | |||
| Inverter idle, 8 h | 20 | 1 | 8 | 160 | Victron 12/3000 zero-load figure, as an example[6] |
| Daily energy from the battery | 1,087 |
The weekend cabin switches its inverter off overnight, so idle counts 8 hours. Starlink and laptop figures are at the high end on purpose.
| Load | Watts | Qty | Hours/day | Wh/day | Where the watts come from |
|---|---|---|---|---|---|
| LED lights | 9 | 6 | 5 | 270 | assumed 9 W bulbs; check yours |
| Refrigerator (350 kWh/yr label) | 40 | 1 | 24 | 959 | assumed EnergyGuide figure; read yours |
| Starlink Mini (high end of average) | 40 | 1 | 24 | 960 | Starlink spec 25–40 W[3] |
| Laptop | 50 | 1 | 8 | 400 | VT Extension list[2] |
| Phone charging | 10 | 2 | 2 | 40 | assumed |
| Well pump | 500 | 1 | 0.5 | 250 | assumed, inside VT range 250–1,100 W[2] |
| AC loads | 2,879 | ||||
| From the battery at 90% inverter efficiency | 3,199 | 2,879 / 0.90 | |||
| Inverter idle, 24 h | 20 | 1 | 24 | 480 | Victron 12/3000 zero-load figure, as an example[6] |
| Daily energy from the battery | 3,679 |
The full-time cabin leaves the inverter on, which adds 480 Wh a day, about 13% of its total. The fridge and pump figures are assumptions; read your own labels. If you have a Starlink Standard kit instead of a Mini, Starlink lists 75–100 W average, which would add roughly 0.9–1.6 kWh a day here.[3]
So the weekend cabin needs about 1,087 Wh a day from the battery and the full-time cabin about 3,679 Wh a day. For comparison, my 3,215 Wh usable would carry the full-time example for a bit under a day with no sun at all.
A "peak sun hour" is one hour of sunlight at 1,000 W per square meter, so a site's daily solar energy in kWh/m² is its peak sun hours. NREL/NLR's solar resource data gives this for US locations as monthly averages on a south-facing surface tilted at the site's latitude, from a satellite model averaged over 1998–2009 on cells about 10 km across.[1] I pulled it for a spread of US cabin country:
| Place | Region | Year average | Lowest month | Lowest month, May–Oct |
|---|---|---|---|---|
| Burlington, VT | Northeast | 4.26 | 2.41 (Dec) | 3.44 (Oct) |
| Asheville, NC | Southern Appalachians | 5.11 | 4.04 (Dec) | 5.03 (Oct) |
| Duluth, MN | Upper Midwest | 4.39 | 2.78 (Dec) | 3.37 (Oct) |
| Missoula, MT | Northern Rockies | 4.75 | 2.56 (Dec) | 4.40 (Oct) |
| Denver, CO | Colorado Front Range | 5.85 | 4.64 (Dec) | 5.76 (Oct) |
| Seattle, WA | Pacific Northwest (west side) | 3.98 | 1.65 (Dec) | 3.18 (Oct) |
| Austin, TX | Texas Hill Country | 5.21 | 4.11 (Dec) | 5.18 (Oct) |
| Flagstaff, AZ | Southwest high country | 6.33 | 5.49 (Dec) | 5.80 (Jul) |
| Hilo, HI | Hawaii Island (east) | 5.12 | 4.38 (Dec) | 5.02 (Oct) |
Fairbanks, AK returned no data from this dataset, so Alaska isn't in the table. NREL/NLR's PVWatts calculator is a better tool for a specific site, and the 1.8 kW solar guide shows month-by-month PVWatts output for six places.
The number that matters most for a cabin is the lowest month you'll actually be there. Burlington's December, at 2.41 hours, is 43% below its year average. Seattle's is 1.65. These are long-term averages. A cloudy week is worse than an average month, and snow on the panels makes a sunny day worthless until it slides off. That's what the battery and the generator are for.
Size the battery from what you can use, not the label. Two planning choices go in:
| Step | Weekend cabin | Full-time cabin |
|---|---|---|
| Daily Wh from the battery | 1,087 | 3,679 |
| x 2 days = usable Wh | 2,173 | 7,358 |
| / 0.80 = nameplate Wh | 2,717 | 9,197 |
| Ah at 12.8 V (12 V LiFePO4) | 212 | 719 |
| Ah at 25.6 V (24 V LiFePO4) | 106 | 359 |
| Ah at 51.2 V (48 V LiFePO4) | 53 | 180 |
Cold cabins need a plan for the battery. EVE allows its LiFePO4 cells to be charged only between 0 and 60 °C (32 to 140 °F).[4] A battery in an unheated mainland cabin can be below freezing on a sunny winter morning, when the panels are ready to charge it. Check your battery or BMS maker's low-temperature charge setting, and think about where the bank lives. The battery runtime guide goes deeper on usable energy and aging.
Panel watts = daily Wh / (peak sun hours x 0.75). The 0.75 is my planning assumption for everything between the panel label and the battery: heat, dirt, wiring, the controller and charging losses. The 1.8 kW guide modeled 14% system losses in PVWatts before the controller and battery take their share, so 0.75 is in that neighborhood, not a measured figure.
| Place | Weekend cabin, sized for its lowest May–Oct month | Full-time cabin, sized for the year average | Full-time cabin, sized for the lowest month |
|---|---|---|---|
| Burlington, VT | 421 W | 1,151 W | 2,035 W |
| Asheville, NC | 288 W | 960 W | 1,214 W |
| Duluth, MN | 430 W | 1,117 W | 1,764 W |
| Missoula, MT | 329 W | 1,033 W | 1,916 W |
| Denver, CO | 252 W | 838 W | 1,057 W |
| Seattle, WA | 456 W | 1,232 W | 2,973 W |
| Austin, TX | 280 W | 941 W | 1,193 W |
| Flagstaff, AZ | 250 W | 775 W | 893 W |
| Hilo, HI | 289 W | 958 W | 1,120 W |
Two things jump out. The weekend cabin is a small system almost anywhere: about 421 W in Burlington for its lowest month from May to October. The full-time cabin is where the north hurts: sized for December, Denver needs about 1,057 W, Burlington about 2,035 W and Seattle about 2,973 W. The alternative to buying panels for the darkest month is to size closer to the average and plan generator time for winter. That trade-off is what the backup generator guide works through.
A charge controller's limit is really a power limit at a given battery voltage. PowMr's manual for its 60 A MPPT controller lists 720 W of panels at 12 V, 1,440 W at 24 V, 2,100 W at 36 V and 2,800 W at 48 V.[5] That's roughly 60 A times the nominal battery voltage. So a rough controller size is panel watts / battery voltage:
Voltage limits matter as much as amps. PowMr says to use the panels' open-circuit voltage (Voc) to make sure the input never exceeds the controller's maximum, 160 V on that model.[5] REC says to work out the number of panels in a string from Voc at the lowest ambient temperature at the site, because Voc rises in the cold, and that the NEC's Article 690 must be followed for the higher-than-label outputs panels see in real conditions.[8] A string that's fine in July can be over the limit on a frozen January morning. This is a good calculation to have your controller maker or an electrician check.
The inverter is sized for power at once, not energy per day. Add up everything that could run at the same moment, then check what starts motors.
For the examples: the weekend cabin's loads at once are a few hundred watts, so a small pure sine inverter covers it. For the full-time cabin, the pump's assumed 1,500 W start alone, plus the fridge, laptop and lights, puts it near 2,000 W for a moment if they overlap. That points at a 2,000 to 3,000 W class unit. Check the start-up figure on your own pump and fridge.
This is the part of a cabin system that can hurt someone or burn the cabin down, and it's the part I'm least willing to summarize. What the manuals say:
I'm not giving wire gauges or fuse ratings on this page on purpose. They depend on current, run length, temperature, the parts you buy and the code your inspector uses. Your equipment manuals and a licensed electrician are the right sources.
| Weekend cabin (Burlington, VT, May–Oct) | Full-time cabin (Denver, CO, year round) | My system, for reference | |
|---|---|---|---|
| Daily use from battery | 1,087 Wh | 3,679 Wh | Not logged |
| Usable battery (2 days) | 2,173 Wh | 7,358 Wh | 3,215 Wh (80% of 4.02 kWh) |
| Panels | about 421 W | about 838 W (average) to 1,057 W (December) | 1,780 W |
| Controller | about 35 A at 12 V | about 35 A at 24 V or 17 A at 48 V | 60 A at 12 V |
| Inverter | small pure sine | 2,000–3,000 W class | 3,000 W |
| Backup | optional | plan on one | Honda EU2200i |
If you've measured a cabin system like these, I'd like to learn from it.
I built GRID COMMAND for this kind of record. You can enter your loads, panels, controller, battery and inverter, see the daily Wh add up, and keep each part's manual next to it, with no signal needed. It's free to try with no account. Saving your system is $5 a month, and the $7 plan adds off-device backup, export and the AI, which answers from your own equipment list and says when something needs an electrician. Open the app.
Start from your daily loads in watt-hours, not from a panel count. Divide the daily Wh by your peak sun hours and by a loss factor (I use 0.75 as a planning assumption). In the worked example on this page, a weekend cabin using about 1,087 Wh a day in Burlington, VT needs about 421 W of panels for its lowest summer-season month. A full-time cabin using about 3,679 Wh a day in Denver needs about 1,057 W for December. Your own loads and location change the answer.
Multiply daily Wh by the days you want to ride through without sun, then divide by the share of the battery you plan to use. With 2 days and 80% usable, the weekend example needs about 2,717 Wh of nameplate LiFePO4 (about 212 Ah at 12.8 V) and the full-time example about 9,197 Wh (about 719 Ah at 12.8 V, or 180 Ah at 51.2 V). The 2 days and 80% are planning choices, not rules.
It's mostly about current. The same power at a higher battery voltage means fewer amps, and so smaller cables and fuses. PowMr's manual for its 60 A controller lists 720 W of panels at 12 V and 2,800 W at 48 V. A weekend cabin often stays at 12 V. A full-time cabin with a fridge and a pump is where 24 V or 48 V starts to make sense. Ask your equipment makers or an electrician before you commit.
Only if you're fine running a generator in the dark months. In NREL/NLR's data, Burlington, VT averages 4.26 peak sun hours over the year but 2.41 in December, so a full-time cabin sized on the average comes up short in winter. Size for the lowest month you'll be there, or plan the generator in from the start.
For anything you aren't sure about, yes. REC's panel manual points to the National Electrical Code (Article 690 for PV) and to qualified system designers, and a lithium bank can deliver hundreds of amps into a fault. Wire sizes, fuses, grounding and any connection to cabin wiring belong to the manuals, the code, your local inspector and an electrician, not to a sizing page.
Cite this page: MiniGridMap, "Off grid solar system for a small cabin: sizing it step by step", https://minigridmap.com/guides/off-grid-solar-system-small-cabin/ (2026). Tables may be reused with a link back.
For the same reference system: How far does a 1.8 kW off-grid solar system go?, How long will my 12 V LiFePO4 battery last? and How big a backup generator does a 12 V LiFePO4 off-grid system need? Once it's built, the off grid solar maintenance checklist covers upkeep, including a cabin that sits empty for months. All guides are on the guides page.
The reference system is the site owner's own. Every figure is arithmetic on cited data and specs, or a labeled assumption. Nothing is measured, and this page is not a system design.